Ordinance Builder
Everything an official or resident needs to write, strengthen, and evaluate a data center ordinance.
How Ratings Work
Use this page to understand how the tracker rates an ordinance and what each score means.
- Quick Check
Ten Core Protections
Ten Core Protections- What it asks
- Does the ordinance include the ten protections residents care about most?
- How it is scored
- Each protection is Strongest Standard, Basic Standard, or Not Addressed. The score is how many of the ten it includes, such as 6 of 10.
- What you see
- The overall coverage rating (Broad, Partial, Narrow, or No coverage) on the map and at the top of every municipality and county page.
- Full Assessment
Category Scorecard
Category Scorecard- What it asks
- How thoroughly does the ordinance cover every topic, including traffic, lighting, and emergency planning?
- How it is scored
- All 52 criteria earn 0, 1, or 2 points, for a total of 104, grouped into eight categories.
- What you see
- A level for each category (Strong, Moderate, Weak, or None) and the total points on each municipality page.
Review Process
An ordinance is rated only from its full text, and every rating is reviewed by the tracker's maintainer before it is published. Where the text could not be read, the entry shows Rating Pending. Proposed ordinances are rated from the posted draft and are labeled as drafts. A municipality whose zoning has no data center rules has 0 of 10 Core Protections, with every protection Not Addressed.
Ten Core Protections
These ten protections reflect the concerns residents raise most often in polls and at Pennsylvania hearings.
Select a card to turn it over and read what the protection requires.
- Protection 1
Expansion Limits
Expansion LimitsRequires a new approval before a data center adds buildings, generators, cooling, batteries, substations, or power demand beyond what was approved.
- Protection 2
Water Supply
Water SupplyRequires public water for cooling where it is available, and a well study before any groundwater is used.
- Protection 3
Cooling Method
Cooling MethodRequires water-saving cooling, such as closed-loop systems.
- Protection 4
Generator and Air Limits
Generator and Air LimitsLimits backup diesel generator testing and air emissions.
- Protection 5
Noise Limit
Noise LimitCaps how loud a data center can be at the property line, as a fixed limit or as an increase over the measured background sound.
- Protection 6
Low-Frequency Noise
Low-Frequency NoiseAddresses the low hum from cooling fans and equipment.
- Protection 7
Public Transparency
Public TransparencyRequires the developer, operator, and end user (or a binding operating profile) to be named, and limits non-disclosure agreements with officials.
- Protection 8
Farmland Protection
Farmland ProtectionKeeps data centers off preserved farmland and protects prime farm soils in the districts where they are allowed.
- Protection 9
Home Setback
Home SetbackRequires a safe distance between nearby homes and a data center, including its outdoor equipment.
- Protection 10
Decommissioning
Decommissioning and ReuseRequires money set aside to remove equipment, fuel, and batteries if the facility closes, and reuse or removal of the building.
Rating Levels
Each of the ten protections is rated at one of three levels.
Coverage Scale
The score is the number of protections addressed at either standard, out of ten.
Coverage counts how many topics an ordinance addresses, not how protective each provision is.
Electricity rates are set by the Pennsylvania Public Utility Commission or by an electric cooperative board, so grid costs are rated as a disclosure requirement and not as a Core Protection.
Category Scorecard
The Category Scorecard rates an ordinance on all 52 criteria, grouped into eight categories. Each criterion earns 0, 1, or 2 points, for a total of 104, and each category receives one of four levels.
Category Levels
Eight Categories
Scoring Rules
- Ratings come only from the full ordinance text: the zoning ordinance, its amendments, and any other adopted ordinance that applies to data centers.
- An ordinance that meets only part of a multi-part 2-point standard earns 1 point.
- A general rule that applies to all uses earns points only if the ordinance says it applies to data centers.
- Criteria 51 and 52 may be met by any adopted ordinance, resolution, or policy.
The 104-point total is reported as a number only. The overall coverage rating always comes from the Core Protections count, and these levels describe a whole category, not a single protection.
All 52 Criteria
Each criterion earns 2 points, 1 point, or 0 points, for a total of 104. An ordinance that falls short of the 1-point standard earns 0 points for that criterion.
Select a category to open its book of criteria.
View All 52 Criteria As A List
Land Use: Criteria 1 to 11
Noise: Criteria 12 to 17
Environment: Criteria 18 to 25
Energy: Criteria 26 to 31
Visual Character: Criteria 32 to 36
Safety: Criteria 37 to 40
Traffic: Criteria 41 to 43
Accountability: Criteria 44 to 52
Status Definitions
Whether a municipality has data center rules at all is shown by its status, not by either rating. The ratings describe how strong the rules are.
Counts of adopted ordinances, and each county’s typical rating and highest rated ordinance, include only the municipalities’ own ordinances, so one county ordinance is not counted dozens of times. County rule coverage is reported beside them, for example on the home page and the For Reporters page.
Public Access
Every entry with an adopted or proposed ordinance also records whether residents can read the ordinance online. Public Access is reported separately and does not change the Core Protections count.
Municipalities with no data center ordinance show "No ordinance" instead, since there is nothing to post.
Changes To The Standard
Tracker Standard version 2.0 (October 29, 2026). After a legal review of all 52 criteria, the standard now rewards the most defensible rule rather than the largest number, and every rated ordinance was rescored.
Expansion Limits replaced Grid Cost Protection as a Core Protection, because Pennsylvania municipalities have no power to decide who pays for grid upgrades. Noise limits tied to the measured background now earn full credit, decommissioning allows reuse of the building, and requirements tied to state permits count when written as conditions of approval. Every rated ordinance was rescored under version 2.0. Where a stricter test could not be confirmed from the recorded evidence, the earlier score stands until the ordinance text is reread.
On October 28, 2026, the protection labels Strongest Standard, Basic Standard and Not Addressed replaced Strong, Moderate, Weak and None; the numbers and colors did not change. On November 4, 2026, a category that earns no points was relabeled None, so that Not Addressed is used only for the ten protections.
Terms used on this page are defined in the Glossary.
Strengthen an Ordinance
The Ordinance Builder sets a standard for each of these 52 criteria, shows which Pennsylvania municipalities already adopted it, and drafts an ordinance for your solicitor.
Glossary
Use this list to look up the zoning terms used on this site, explained in plain language.
Ways a Data Center Can Be Approved
How an ordinance lets a data center in, from the least review to the most.
- Permitted by Right
- A use that is allowed without a hearing, as long as the project meets the written standards in the ordinance.
- Conditional Use
- A use the zoning ordinance allows only after the elected governing body, such as the supervisors, commissioners, or council, holds a public hearing and finds that every condition in the ordinance is met. Residents may testify at the hearing.
- Special Exception
- A use the zoning ordinance allows only after the Zoning Hearing Board holds a public hearing and finds that every condition in the ordinance is met. Residents may testify at the hearing.
- Variance
- Permission from the Zoning Hearing Board to depart from a zoning requirement because of a hardship unique to the property.
Changing the Rules
The steps a township, borough, or city takes to add or change data center rules.
- Zoning Amendment
- A change to the text of the zoning ordinance or to the zoning map. It follows the same review, hearing, and vote steps as a new ordinance.
- Rezoning
- Changing the zoning district of particular parcels on the zoning map, for example from agricultural to industrial.
- Overlay District
- An area drawn on top of the regular zoning map that adds rules for one kind of use, such as data centers, only on the mapped parcels.
- Curative Amendment
- A process under the Pennsylvania Municipalities Planning Code for fixing part of a zoning ordinance that is claimed to be invalid. When a municipality starts one itself, it has 180 days to adopt the fix, and challenges to that part are put on hold.
- Moratorium
- A temporary hold on accepting or approving certain applications while the municipality writes new rules.
- First Reading
- The first time a city or borough council formally reads a proposed ordinance. A final vote usually comes at a later meeting.
- Public Hearing
- A meeting advertised in advance where anyone may speak or submit comments before officials decide. Pennsylvania law requires one before a zoning ordinance or amendment is adopted.
Boards and Plans
The bodies and documents that shape local land use decisions.
- Planning Commission
- An appointed advisory body that reviews proposed zoning changes and development plans and recommends what the elected governing body should do. It does not adopt ordinances.
- Zoning Hearing Board
- An appointed board that decides special exceptions, variances, and appeals of the zoning officer's decisions, after a public hearing.
- Comprehensive Plan
- A municipality's long-range plan for land use. Zoning is supposed to carry out the plan, but the plan itself does not regulate any property.
- SALDO
- The Subdivision and Land Development Ordinance, which sets the rules for dividing land and for site plans, such as roads, stormwater, and landscaping.
Standards in an Ordinance
Terms that appear in the protections an ordinance sets.
- Setback
- The minimum distance a building or piece of equipment must be from a property line, a home, or another feature.
- dBA
- A measure of sound level weighted to match how people hear. Lower numbers are quieter; a 10 dBA increase sounds about twice as loud.
- dBC
- A measure of sound level that gives more weight to low-frequency sound, such as the hum of cooling equipment, which dBA limits can miss.
- Battery Energy Storage System
- Large batteries that store electricity on site, often used for backup power at data centers.
- Decommissioning
- Removing a facility and restoring the site when it closes. A decommissioning bond is money the owner sets aside so the municipality can do the work if the owner does not.
- Sensitive Receptor
- A place where people are especially affected by noise or pollution, such as a home, school, hospital, nursing home, park, or place of worship. Ordinances often measure setbacks and noise limits from the nearest sensitive receptor.
- Tier 4
- The strictest federal emission standard for new diesel engines, including backup generators. Tier 4 engines release far less soot and nitrogen oxides than older engines.
- Closed-Loop Cooling
- A cooling system that circulates the same water or coolant in sealed pipes and needs only small top-ups, instead of drawing large amounts of water and evaporating it.
Rights, Records, and Appeals
How residents get information and challenge decisions.
- Right-to-Know Request
- A written request for public records under Pennsylvania's Right-to-Know Law. The municipality must respond within five business days or say it needs up to 30 more days, and a denial can be appealed to the Office of Open Records.
- Nondisclosure Agreement
- An agreement in which officials promise to keep information about a project, such as the developer's or end user's name, confidential. Some ordinances require that any such agreement be disclosed to the public.
- Exclusionary Zoning
- Zoning that leaves no reasonable place in a municipality for a lawful use. Pennsylvania courts can strike down such zoning, often after a developer files a curative amendment or a validity challenge.
- Land Use Appeal
- An appeal of a zoning or land use decision to the county Court of Common Pleas. Applicants and residents recognized as parties at the hearing generally have 30 days after the written decision to file.
No terms match your search.